11/19/2024 6:41 a.m.
http://cablematic.iskra.cat/en/products/cpu-fan-socket-603-slim-2u-intel-piv-xeon-VU052/
http://cablematic.iskra.cat/en/products/cpu-fan-socket-603-slim-2u-intel-piv-xeon-VU052/
PVP
€13.37
€2.41
Price including VAT:
€2.41
PVD
€11.75
€2.12
PVP: Retail price.
Check conditions.
PVP: Sale price to distributors.
Check conditions.
2 years
warranty
warranty
14 days
returns
returns
OUTLET
Specifications
- Compatible Intel Pentium 4 XEON (3060Hz).
- Compatible with Socket 603.
- Total Size: 89 x 70 x 50 mm.
- Weight: 489 g.
- Manufactured in aluminum with copper core.
More info
Fan with radiator made of copper and aluminum to be installed on an Intel Pentium 4 XEON processor with Socket 603. Ideal to be installed on servers 1U high.
Specifications
Specifications
- Compatible Intel Pentium 4 XEON (3060Hz).
- Compatible with Socket 603.
- Total Size: 89 x 70 x 50 mm.
- Weight: 489 g.
- Manufactured in aluminum with copper core.
- Fan size: 70 x70 x 15 mm.
- Radiator size: 89 x 70 x 35 mm.
- Voltage: 12VDC (3-pin connector).
- Fan speed: 4000 ± 10% RPM.
- Noise level: 28 dBA.
- Air flow: 27.96 CFM (max.).
- Gross Weight: 450 g
- Number of packages: 1
Technical terms
- Rack unit (U)
- Revolutions per minute (rpm)
Rack unit (U)
There are several cabinet heights according to the needs of the installation, this height can be measured in rack units (U).
Each rack unit or U is the distance between each horizontal separation to place the different accessories inside the rack. This distance is 1.75 inches that is equal to 4.4445 cm high.
For example, if we say that a rack is 8U we will understand that it has 8 units to install device orAccessories of 4.44 cm in height.
Normally these accessories, like trays, guides, strips, etc. Occupy a unit of U (1U), but we can find that other devices or accessories occupy more units, for example can be a rack box to install a PC, a UPS, etc. It can be said that there is also a half unit of U (0.5U), in this case, two units could be installed in a rack unit.
As far as I knowEndo the units of rack that occupy the devices that we are going to install we will know the height that we need for our rack.
The size of the rack unit (U) is based on the standard specification for racks defined in EIA-310.
Each rack unit or U is the distance between each horizontal separation to place the different accessories inside the rack. This distance is 1.75 inches that is equal to 4.4445 cm high.
For example, if we say that a rack is 8U we will understand that it has 8 units to install device orAccessories of 4.44 cm in height.
Normally these accessories, like trays, guides, strips, etc. Occupy a unit of U (1U), but we can find that other devices or accessories occupy more units, for example can be a rack box to install a PC, a UPS, etc. It can be said that there is also a half unit of U (0.5U), in this case, two units could be installed in a rack unit.
As far as I knowEndo the units of rack that occupy the devices that we are going to install we will know the height that we need for our rack.
The size of the rack unit (U) is based on the standard specification for racks defined in EIA-310.